Opening book details…
Can I read Railway applications. Fixed installations. Particular requirements for alternating current switchgear. Circuit-breakers with nominal voltage above 1 kV on EtoBox?
Railway applications. Fixed installations. Particular requirements for alternating current switchgear. Circuit-breakers with nominal voltage above 1 kV by British Standards Institute Staff is a reference work available to read on EtoBox.
What is Railway applications. Fixed installations. Particular requirements for alternating current switchgear. Circuit-breakers with nominal voltage above 1 kV about?
This standard BS EN 50152-1:2012+A1:2013 Railway applications. Fixed installations. Particular requirements for alternating current switchgear is classified in these ICS categories:. 29.280 Electric traction equipment. 29.120.40 Switches. This EN 50152-1 is applicable to single-pole and two-pole alternating current (a.c.) circuit-breakers which are:. for indoor or outdoor fixed installations in tractions systems, and. operated with an a.c. line voltage and frequency as specified in EN 50163. NOTE 1 EN 50163 specifies the a.c. traction systems 15 kV 16,7 Hz and 25 kV 50 Hz. NOTE 2 As rails of a.c. traction systems are connected to earth and included in the return current path all phase to earth voltages will be within the tolerances as specified in EN 50163. Nevertheless phase to phase voltages are sometimes higher e.g. in autotransformer systems. This European Standard is also applicable to the operating devices of circuit-breakers and to their auxiliary equipment. This European Standard does not address circuit-breakers with dependent manual operating mechanism. NOTE 3 It is impossible to specify a rated short-circuit making current for these circuit-breakers and it is likely that
Who reads Railway applications. Fixed installations. Particular requirements for alternating current switchgear. Circuit-breakers with nominal voltage above 1 kV?
It is typically read by working professionals who need an authoritative practice reference.
Common subject areas: medicine, law, business, engineering.
- Author
- British Standards Institute Staff
- Publisher
- BSI British Standards Institution
- Published
- 2013
- Language
- EN
- ISBN
- 9780580828645
- Category
- reference
More by British Standards Institute Staff
Browse all works by British Standards Institute Staff
Similar books
- Railway Applications. Fixed Installations. D. C. Switchgear. D. C. Circuit Breakers — British Standards Institute Staff (2003)
- Railway Applications. Fixed Installations. D. C. Switchgear. D. C. Switchgear Assemblies — ReeveG (2003)
- Railway Applications. Fixed Installations. D. C. Switchgear. Outdoor D. C. Disconnectors, Switch-disconnectors And Earthing Switches — British Standards Institute Staff (2013)
- Specification for High-voltage Alternating Current Circuit-breakers. Guide for Seismic Qualification of High-voltage Alternating Current Circuit-breakers. — BSB (1999)
- High-voltage Switchgear and Controlgear. Switches for Rated Voltages Above 1 kV Up to and Including 52 kV — JAYNE BROOKS (2013)
- Railway Applications. Fixed Installations. D. C. Switchgear. Measurement, Control and Protection Devices for Specific Use in D. C. Traction Systems. Isolating Voltage Transducers and Other Voltage Measuring Devices — 标准分享网 (2009)