ICAC Emission Monitoring Test Method by Santiago Montalvan is a document available to read on EtoBox.
This document provides a test method for using a portable electrochemical analyzer to determine concentrations of oxygen, carbon monoxide, and oxides of nitrogen from stationary sources. It describes the applicability and principles of the method, the required measurement system components, definitions of key terms, and performance specifications for the analyzer. The method involves extracting a gas sample from a stack, conveying it to the analyzer, and measuring concentrations over multiple measurement cy