Split Ring Connector Spacing Guidelines by CarlitosIbanez is a document available to read on EtoBox.
This document discusses the minimum spacing requirements for shear plate and split ring connectors used in wood construction. The minimum spacing is 3.5 inches for 1/2 inch thick plates and 5 inches for 4 inch connectors. If the spacing is between the minimum and the spacing for a geometry factor of 1, the geometry factor is determined by linear interpolation. The geometry factor affects the design values used for both parallel and perpendicular forces on the connectors. Examples are provided to demonstrate