Unit Hydrograph Solution Example by Parikshit Yadav is a document available to read on EtoBox.

The document outlines a solution to a Unit Hydrograph and Direct Runoff problem involving a catchment area of 330 km² over an 18-hour duration. It calculates direct runoff by subtracting baseflow from runoff data, resulting in a total volume of 1.7118 × 10^7 m³ and a depth of 5.187 cm. Finally, it computes the Unit Hydrograph ordinates by dividing direct runoff values by the calculated depth, yielding specific ordinates in cumecs/cm.