GSM Handover and Cell Reselection Analysis by saeedtarkian is a document available to read on EtoBox.
The 900 MHz cell has a C1 value of 20 dB while the 1800 MHz cell has a C1 value of 13 dB after applying the cell selection offsets. However, to prefer the 1800 MHz cell, the C2 criteria could be used by setting the penalty time to less than 640 seconds and the temporary offset to 0 dB for the 1800 MHz cell, which would make its C2 value higher than the 900 MHz cell