The study compares the performance of shell and tube versus helical coil heat exchangers in ammonia-water vapour absorption refrigeration systems. Results indicate that the helical coil configuration significantly reduces the required heat transfer area by 56% and increases the overall heat transfer coefficient by 130% compared to the shell and tube design. This improvement is attributed to the secondary flow induced by the coil