What is UT Inspection Report for Ruby WHP-PQP Cellar about?
1) The report summarizes an ultrasonic thickness inspection of straight pipes and elbows on the 12-PT-10012-A09D line at the Ruby WHP-PQP Cellar. 2) Measurements were taken at multiple points around each component and compared to the nominal thickness. The minimum readings ranged from 27.77mm to 30.52mm. 3) The inspection found the pipewall thicknesses to be within acceptable tolerances and the surfaces to be in a painted condition.