Opening book details…
Can I read High-throughput simultaneous determination of the HIV protease inhibitors indinavir and L-756423 in human plasma using semi-automated 96-well solid phase extraction and LC–MS/MS on EtoBox?
High-throughput simultaneous determination of the HIV protease inhibitors indinavir and L-756423 in human plasma using semi-automated 96-well solid phase extraction and LC–MS/MS by M.J Rose; S.A Merschman; R Eisenhandler; E.J Woolf; K.C Yeh; L Lin; W Fang; J Hsieh; M.P Braun; G.J Gatto; B.K Matuszewski is a Chemistry article available to read on EtoBox.
What is High-throughput simultaneous determination of the HIV protease inhibitors indinavir and L-756423 in human plasma using semi-automated 96-well solid phase extraction and LC–MS/MS about?
A method for the simultaneous determination of the HIV protease inhibitors indinavir and L-756423, in human plasma has been developed. Plasma samples (0.5 ml) were extracted using a 3M Empore 96-well plate in the mixed phase cation exchange (MPC) format. The extraction method was automated through the application of both the Packard 204DT and TOMTEC Quadra 96 work stations, and the resulting extracts were analyzed using a PE-Sciex API-3000 LC-MS/MS with a heated nebulizer interface (500 degrees C). The assay was linear in the concentration range 1-2500 ng/ml for indinavir and 5 2500 ng/ml for L-756423 when 0.5-ml aliquots of plasma were extracted. Recoveries of indinavir and L-756423 were greater than 76 and 80%, respectively, over the calibration curve range when using the described sample preparation method. Within-batch precision and accuracy for the quantitation of indinavir over the range 1-2500 ng/ml were 5.4% R.S.D. or less and within 4.0%, respectively. Within-batch precision and accuracy for the quantitation of L-756423 over the range 5-2500 ng/ml were 5.3% R.S.D. or less and within 3.4%, respectively. Interbatch variability for the analysis of indinavir QC samples at low
Who reads High-throughput simultaneous determination of the HIV protease inhibitors indinavir and L-756423 in human plasma using semi-automated 96-well solid phase extraction and LC–MS/MS?
It is typically read by researchers, students, and practitioners in Chemistry.
- Author
- M.J Rose; S.A Merschman; R Eisenhandler; E.J Woolf; K.C Yeh; L Lin; W Fang; J Hsieh; M.P Braun; G.J Gatto; B.K Matuszewski
- Publisher
- Elsevier Science; Elsevier ; Elsevier BV (ISSN 0731-7085)
- Published
- 2000
- Language
- EN
- Field
- Chemistry (Physical Sciences)