Skip to content

Opening book details…

About this document

Collapse Voltage of CMUT Membrane Analysis by nhtan.sdh222 is a document available to read on EtoBox.

The paper presents a semi-analytical method for calculating the collapse voltage of capacitive micromachined ultrasonic transducer (CMUT) membranes, which significantly reduces computation time compared to traditional finite element method (FEM) analysis. By using a parallel plate approximation and analytical solutions for membrane deflection, the proposed algorithm achieves high accuracy (within 0.1 percent) in just a few seconds. The results indicate that this method is effective for various design struct

Author
nhtan.sdh222
Language
EN