Can I read Capacitor Reforming for ACS 600 Drives on EtoBox?

Capacitor Reforming for ACS 600 Drives by tetrix is a document available to read on EtoBox.

What is Capacitor Reforming for ACS 600 Drives about?

The document provides guidance on reforming or re-aging capacitors in ABB Industry Oy ACS 600 frequency converters and drive units after they have been in storage or non-operational for extended periods. It describes two methods for reforming capacitors that have been inactive for over two years using either an external rectifier and resistor circuit or a controlled DC power supply. The required reforming times range from 1 to 6 hours depending on how long the converter has been inactive.