About this document
Water Pumping Project - Vc0-Report by Kennedy Tembo is a document available to read on EtoBox.
The simulation report for the ST CHRISTOPHER WATER PUMPING project in Nyamira, Kenya, details a pumping PV system with a power capacity of 9.84 kWp. The system is designed to meet a water demand of 10 m³/day, but it only pumped 665 m³, resulting in a significant water shortfall of 81.8%. The report includes various performance metrics, such as a system efficiency of 7.8% and pump efficiency of 20.6%, along with detailed loss diagrams and monthly production data.
- Author
- Kennedy Tembo
- Language
- EN