Secant Method for Specific Heat Calculation by Vicente Graves is a document available to read on EtoBox.

The document describes using the secant method to iteratively calculate the temperature corresponding to a specific heat of 1.2 Kj/KgK. It shows four iterations of the method, with the initial temperatures of 1100K and 1200K, and the temperatures and function values converging to 1182.096K over the iterations.