Nitrogen helium leak testing is a method used by Baker Hughes to verify the integrity of pressurized systems prior to introducing operating medium. It can detect leaks as small as 5 scf/year and involves sealing potential leak sources, pressurizing the system with a helium-nitrogen mixture, and using a probe connected to a mass spectrometer or handheld detector to sample for helium at leak sources. Any leaks above the acceptable threshold are identified and the system is then ready for hydrocarbon introduct