Nasik Thermal Power Station Event Report by SE EST is a document available to read on EtoBox.

The event analysis report summarizes a forced outage at the Nasik Thermal Power Station Unit 4. Key details include: - The unit capacity is 210MW. The event occurred on November 3, 2013 after 0 days since the last synchronization. - At the time of the event, the unit was operating at 150MW with oil support from cylinders AB and CD. - The turbine auto stop (T.A.S) tripped on closing of the left IV due to a burnt and shorted cable in the left IV close limit switch. - Remedial actions taken were replacing the