This document outlines specifications for backfilling trenches after sewer installation. It details 5 classes of backfill material from ordinary soil to cement slurry and their compaction requirements. Backfill must be compacted in layers, with the bottom layers having a maximum thickness of 150mm and upper layers requiring greater compaction to at least 95% of standard. Contractors must test compaction every 50 meters using an approved method. Temporary bituminous sealing is also required over backfilled t