Can I read A 6-hour nocturnal interruption of a continuous subcutaneous insulin infusion: 1. Metabolic and hormonal consequences and scheme for a prompt return to adequate control on EtoBox?

A 6-hour nocturnal interruption of a continuous subcutaneous insulin infusion: 1. Metabolic and hormonal consequences and scheme for a prompt return to adequate control by G. Krzentowski; A. Scheen; M. Castillo; A. S. Luyckx; P. J. Lefèbvre is a Medicine article available to read on EtoBox.

What is A 6-hour nocturnal interruption of a continuous subcutaneous insulin infusion: 1. Metabolic and hormonal consequences and scheme for a prompt return to adequate control about?

Interruption of a continuous subcutaneous insulin infusion, most often due to technical problems occurring during the night, is a not uncommon event whose metabolic consequences have received relatively little attention until now. We have therefore investigated the changes in blood glucose, plasma non-esterified fatty acids, 3-hydroxybutyrate, glucagon and free insulin in eight C-peptide negative Type 1 diabetic patients whose pumps were deliberately stopped between 23.00 h and 05.00 h. A control test with the pump functioning normally was carried out in each patient and the studies were randomized. Considering the values at 23.00 h as reference, interruption of the insulin infusion resulted in (1) a rapid decrease in plasma free insulin significant after 1 h and reaching a nadir of 6 +/- 2 mU/l after 6 h; (2) a rise in blood glucose which was significant at hour 3 and reached 17.4 +/- 1.9 mmol/l at hour 6; (3) a moderate increase in plasma nonesterified fatty acids which remained in the range of 700-800 mumol/l; (4) an early and linear rise in plasma 3-hydroxybutyrate, significant after 1 h and averaging 1290 +/- 140 mumol/l after 6 h; (5) a late increase (hour 5) in plasma glucag

Who reads A 6-hour nocturnal interruption of a continuous subcutaneous insulin infusion: 1. Metabolic and hormonal consequences and scheme for a prompt return to adequate control?

It is typically read by researchers, students, and practitioners in Medicine.

Author
G. Krzentowski; A. Scheen; M. Castillo; A. S. Luyckx; P. J. Lefèbvre
Publisher
Springer; Springer-Verlag; Springer Verlag; Springer Science and Business Media LLC (ISSN 0012-186X)
Published
1983
Language
EN
Field
Medicine (Health Sciences)

More by G. Krzentowski; A. Scheen; M. Castillo; A. S. Luyckx; P. J. Lefèbvre

Browse all works by G. Krzentowski; A. Scheen; M. Castillo; A. S. Luyckx; P. J. Lefèbvre