About this document
Microfluidic Platform Design Protocol by Dhyially Stroe is a document available to read on EtoBox.
The document describes designing a microfluidic platform with the following key details: 1. It will trap cells and culture aggregates in squared chambers using a negative photoresist. 2. The mask aligner uses a 1000W mercury lamp filtered to the i-line region and optics that decrease light intensity by 50% on a 6" surface. 3. The mask and lithography protocol are provided to fabricate channels and chambers of specific dimensions on an SU-8 coated wafer.
- Author
- Dhyially Stroe
- Language
- EN