About this document

MGP10 Timber Bending Stiffness Analysis by timmo510 is a document available to read on EtoBox.

The analysis of QC test data for 35 x 138mm MGP10 timber produced on 6th March 2017 indicates that it exceeds the required bending stiffness and strength for MGP10 grade. The average bending stiffness was measured at 12.52 GPa, surpassing the minimum requirement of 10.0 GPa, and all specimens exceeded the required bending strength of 17 MPa. Overall, the results confirm that the product meets and exceeds the standards set by AS/NZS 4063:2010.

Author
timmo510
Language
EN