About this document
Orsat Apparatus for Flue Gas Analysis by BalRam Dhiman is a document available to read on EtoBox.
The Orsat gas apparatus consists of four main components: [1] a caustic potash solution to absorb carbon dioxide, [2] an alkaline pyrogallic acid solution to absorb oxygen, [3] cuprous chloride solutions to absorb carbon monoxide, and [4] a burette to measure the gas volumes. The procedure involves drawing a gas sample into the burette and then passing it through each solution pipette to absorb the different components sequentially. Volume percentages are determined from burette readings and can be converte