Completion Report KM SINABUNG, GEN 3. by unhasmursalin is a document available to read on EtoBox.
The completion report details the vibration surveillance of Generator #3, indicating that the overall vibration level is at a warning status, particularly high at the Generator NDE Axial. Recommendations include inspecting and replacing rubber mountings, flexible coupling parts, and checking bearings due to potential mechanical looseness. Regular vibration monitoring is advised to ensure the health of the machinery.