Implant Surface Roughness and Stability Review by edu is a document available to read on EtoBox.

This systematic review investigates the correlation between dental implant surface roughness and implant stability from placement to three months post-operation. The review included 11 studies, revealing no significant correlation between surface roughness and primary stability, but a correlation between roughness and osseointegration was noted, particularly related to secondary stability. The authors emphasize the need for standardized methodologies to facilitate better comparisons and conclusions in futur