Common Base Amplifier Lab Analysis by Souban Javed is a document available to read on EtoBox.
This document describes an electronics lab experiment on a common base amplifier. Key findings include: 1) The common base amplifier circuit was implemented and its gain was measured to be approximately 2V. 2) The phase difference between the input and output signals was 30 degrees. 3) The input impedance of the common base amplifier circuit was calculated to be 0.0249 ohms. 4) Voltage measurements were taken at different points in the circuit and impedances were calculated and compared to theoretical