Siphon System Height Calculation by Phyu Mar Thein Kyaw is a document available to read on EtoBox.

This document contains calculations for a pumping system for the Pandan I Pumping Station. It details: - The system will pump 1200 liters per second of water at 32 degrees Celsius. - The main pipe is 150 meters long with an internal diameter of 1050 mm. - It calculates losses from friction, fittings and other factors to determine the total system head loss is 0.42 meters. - It then calculates the required height of the siphon system as 6.81 meters, but recommends using 75-80% of this value.

Author
Phyu Mar Thein Kyaw