Charging Car Load Cell Calibration Guide by Anuj Gautam is a document available to read on EtoBox.
(1) This document provides instructions for calibrating the load cells of a charging car. It describes checking the load cell wiring and output voltages, and ensuring the hopper is empty before starting calibration. (2) The calibration procedure involves entering a password to access the calibration menu, confirming or adjusting the capacity value, recording the offset value with an empty hopper, and adjusting the span value by loading coal until the hopper reaches maximum. (3) Once calibration is compl