Column Load and Safety Analysis by 3ces is a document available to read on EtoBox.

This document contains calculations for determining the minimum required thickness of concrete slabs for three column designs: 1) An inner column with dimensions 30 cm by 110 cm requiring a slab thickness of at least 137.5 cm 2) An edge column with dimensions 20 cm by 30 cm requiring a slab thickness of at least 17.5 cm 3) A corner column with dimensions 20 cm by 30 cm also requiring a slab thickness of at least 17.5 cm