ZXB Bearing Connection Design Analysis by Andres Felipe Tobon Señas is a document available to read on EtoBox.

1. The document describes the design of a beam to column connection using four bolted extended unstiffened end plates. 2. Key design checks are performed including determining required bolt diameter, end plate thickness, checking bolt and weld strengths. 3. Additional checks are required for the column including calculating required stiffener design force and performing panel zone and stiffener checks since the column web is inadequate. An alternative is to use web doublers and transverse stiffeners.