About this document
Steam Pipe Sizing Calculations Guide by Minh Tran is a document available to read on EtoBox.
This document contains calculations for sizing steam pipes based on known steam flow rate, pipe length, pressure loss, and velocity. It shows that for a steam flow rate of 203.03 kg/hour through a 29 meter long, 0.08 meter diameter pipe, the expected pressure loss is 3051.55 Pascals or 0.03052 bar. It also checks that the calculated steam velocity of 13.92 m/s is consistent with the given steam flow rate and pipe dimensions.
- Author
- Minh Tran
- Language
- EN