Heat Exchanger Performance Data Analysis by Fitri Gina Gunawan is a document available to read on EtoBox.

1. The document presents data from experiments on three heat exchangers: a shell and tube heat exchanger and two double pipe heat exchangers (HE-1 and HE-2). It includes inlet and outlet temperatures and flow rates. 2. Calculations are shown for heat transfer (Q), log mean temperature difference (LMTD), and overall heat transfer coefficient (U) for each experiment. The parameters depend on the flow rates of hot and cold fluids. 3. Equations used to calculate mass, heat transfer, LMTD, and U are outlined

Author
Fitri Gina Gunawan
Language
EN