Opening book details…
Can I read Microporous TiO2 membranes with a cut off <500 Da on EtoBox?
Microporous TiO2 membranes with a cut off <500 Da by P. Puhlfürß; A. Voigt; R. Weber; M. Morbé is a Engineering article available to read on EtoBox.
What is Microporous TiO2 membranes with a cut off <500 Da about?
Microporous TiO 2 membranes were developed by a polymeric sol-gel technique on top of a specially designed tubular ceramic multi-layer support. The microporosity of the membrane is 28% and depends strongly on the amorphous state of the TiO 2 . N 2 -sorption measurements indicated cylindrical pores with a mean diameter of 0.9 nm which was confirmed by filtration tests using molecular weight standards. The membrane has a cut off of 480 Da and a pure water flux of 20 l/(m 2 h bar). Salt retention depends on the pH and the salt concentration. At a pH above 5.8, the retention of sulphate ions is more than 90%.
Who reads Microporous TiO2 membranes with a cut off <500 Da?
It is typically read by researchers, students, and practitioners in Engineering.
- Author
- P. Puhlfürß; A. Voigt; R. Weber; M. Morbé
- Publisher
- Elsevier Science; Elsevier ; Elsevier BV (ISSN 0376-7388)
- Published
- 2000
- Language
- EN
- Field
- Engineering (Physical Sciences)