Opening book details…
Can I read Evaluating Confined Aquifer Pumping Tests on EtoBox?
Evaluating Confined Aquifer Pumping Tests by etsimo is a document available to read on EtoBox.
What is Evaluating Confined Aquifer Pumping Tests about?
1) The document describes methods for evaluating pumping tests in confined aquifers under steady-state and unsteady-state flow conditions. 2) It analyzes data from a pumping test where a well pumped a confined sand and gravel aquifer at a constant rate of 9.12 liters/second for 14 hours. 3) Using the Thiem method under transient steady-state conditions between 10-14 hours, the transmissivity of the aquifer was calculated to be approximately 385 square meters per day based on drawdown readings from piezo