Skip to content

Opening book details…

Can I read Cycle Time Analysis of Electric Loaders on EtoBox?

Cycle Time Analysis of Electric Loaders by gokul is a document available to read on EtoBox.

What is Cycle Time Analysis of Electric Loaders about?

- The document analyzes the cycle time phases and target load of electric mining loaders using data from performance monitors on two 21m3 electric loaders. - The average total cycle time was 49.69 seconds. Travel to dump took the most time at 50.57% of the cycle, while digging took the least time at 10.71% of the cycle. - Travel to dig was broken down into reverse (39.14% of travel to dig phase) and forward (60.86% of travel to dig phase) motions.

Author
gokul
Language