About this document
Heat Exchanger Design and Area Calculation by Muhammad Saad Shaukat Ahmad is a document available to read on EtoBox.
This document outlines the design process for a shell and tube heat exchanger. It provides the specifications for a problem involving heating water from 30 to 80 degrees C using hot exhaust gases. The required steps are shown, including determining heat transfer rates, effectiveness, and NTU. The calculated required surface area is 6.612657 m2. A heat exchanger is selected from a catalog with an area of 72.4 sq. ft. that approximates this value. Design considerations for material selection and applications
- Author
- Muhammad Saad Shaukat Ahmad
- Language
- EN