This document summarizes calculations to check that the net positive suction head (NPSH) available for pumps GA-602/R is higher than the NPSH required, given operating parameters. The calculations show that with a specific gravity of 0.5285, operating pressure of 138 psig, vapor pressure of 152.651 psia, pressure loss of 0.485 psi, and minimum height of 10.26 ft, the NPSH available is 8.354304636 ft, which is higher than the required NPSH of 1.7 ft according to the supplier.