What is Distillation Column Control Strategies about?
The document discusses selecting a control strategy for a distillation column. It evaluates three types of strategies - LV, LB, and DV configurations. Material flows through the column are calculated as 32.5 kg/hr for external/internal liquid and 68.5 kg/hr for vapor. The LV configuration is identified as the best strategy as it has independent level control tuning, reduces disturbances, and performs better with dead-times. It controls the boiler and reflux drum with level (L) and vapor (V) as degrees of fr