Skip to content

Opening book details…

Can I read Distillation Column Control Strategies on EtoBox?

Distillation Column Control Strategies by Nethiyaa is a document available to read on EtoBox.

What is Distillation Column Control Strategies about?

The document discusses selecting a control strategy for a distillation column. It evaluates three types of strategies - LV, LB, and DV configurations. Material flows through the column are calculated as 32.5 kg/hr for external/internal liquid and 68.5 kg/hr for vapor. The LV configuration is identified as the best strategy as it has independent level control tuning, reduces disturbances, and performs better with dead-times. It controls the boiler and reflux drum with level (L) and vapor (V) as degrees of fr

Author
Nethiyaa
Language
EN